Divert valve SC

Divert valve SC

Reliable flow direction control in a hygienic production process 

-    Two-part valve disc, screwed, with a defined space for the sealing ring for easy installation

-    Seal resistant to seepage and ripout 

-    Shaft seal design: 

  •     Stripping function protects against contamination ingress
  •     Geometry protects the seal against being torn out

Version SC

-    Actuator allocation according to product pressure: 

  •     6 bar (87 psi) / 10 bar (145 psi) / 22.7 bar (330 psi)

-    Application with higher product pressures up to 22.7 bar (330 psi) and to avoid pressure surges 

-    Valve disk double-balanced

  •     resistant to pressure blows up to min. 45 bar (652 psi)
  •     avoidance of pressure surges during switching

-    Housing PN 25 without dead space

  •     one part, for welding – no additional connections (screw connection, flange, etc.) required in the pipeline
  •     drainable- no sump in the upper housing 

-    Variable flow direction

Version SC2

-    Cost-effective alternative - connection 0 to gully

-    Actuator allocation to product pressure 6 bar (87 psi), 10 bar (145 psi)